XRD Equipment Model D5000 manufactured by SIEMENS, Germany
X-ray scattering is an analysis technique with a wide range of applications. The reason this method has recently gained significant importance is that it is a non-destructive bridge to the nanoworld. This technique has very extensive applications in the fields of science, research, and quality control in the glass, cement, geology, pharmaceutical materials, catalysts, polymers, metals, and nanomaterials industries. This technique is applicable for both qualitative and quantitative identification. Qualitative identification involves phase identification, which is performed by comparing the obtained peaks from the sample with the information available in the software library. Quantitative identification involves determining the distance between crystal planes and the degree of crystallinity.
| Test Accuracy | Resolution | Measurement Range (2θ) | Equipment Name |
| ±0.02 | 0.01 Degree | 5-70 Degrees | XRD |
Test Standards:
BSEN 13925-2005, ASTM D 5380-93(2014)
Suitable Sample for Testing:
Samples should be powdery (approximately 1 gram) with an approximate particle size of 45 microns. Care should be taken that when touching the powder, it should not feel rough.
For non-powdery samples (sheets, films, fibers, etc.), care should be taken that access to a smooth and defect-free surface is possible. If samples are in the form of square sheets and films with dimensions of 3cm ×3cm, they are suitable.
SWAXS Device

SWAXS Equipment Model S3-micropix manufactured by HECUS, Austria
X-ray diffraction can be applied at three length scales: 1, 10, and 100 nanometers, corresponding to wide angle, small angle, and ultra-small angle methods. Structures at length scales larger than a unit cell (approximately 10 nanometers instead of 1 nanometer) can be studied using the SAXS method. It should be noted that the methodology for this analysis has been extensively developed and can be found in any standards book. Just as WAXD can help in studying the orientation of crystals and the placement of chains within these crystals, SAXS is used to study electron density fluctuations that occur due to structural inhomogeneity at much larger distances. SAXS is widely used to study layered structures by measuring parameters such as layer thickness and height, layer diameter, and the thickness of the interlayer between the crystalline and amorphous regions. In fiber analysis, SAXS can provide information regarding the morphology of filaments and fiber diameter, orientation, and inhomogeneities at larger scales such as pores, defects, cracks, and gaps. This information is somewhat similar to what is obtained from TEM, but with a major difference: SAXS requires no sample preparation, and the information obtained by this method relates to an average area of more than 0.1 square millimeters. Furthermore, SAXS is also used to study the conformation, size, and dynamics of polymers in solutions and gels.
| Resolution | Measurement Range (2θ) | Equipment Name |
| 0.01 Degree | 0-8 Degrees | SWAXS |
Suitable Sample for Testing:
Powder Samples: They should be soft and homogeneous.
Liquid Samples: They should form stable emulsions.
Sheet Samples: Dimensions of 2cm × 2 cm, thickness depends on the mass absorption coefficient of the material.
Gel or Paste Samples
Film Samples in dimensions of 2cm × 2cm